BPC-157 certificate of analysis: lot APL-BPC10-2608-03

Compound
BPC-157
Lot
APL-BPC10-2608-03
Laboratory
Supplier lab
Test
purity · HPLC
Result
99.12%
Tested
17 Aug 2026
Covers stock
Not current stock

BPC-157 10 mg from batch APL-BPC10-2608-03 was analysed on 17 August 2026 and measured 99.12% purity by HPLC / Mass Spectrometry, passing all 5 release tests.

Purity

99.12%

Result

All 5 tests passed

Tested

17 August 2026

Method

HPLC / Mass Spectrometry

Net content

10.08 mg

Independent verification

BPC-157 10 mg is independently verified by Ozcanium Analytics, an independent Australian laboratory, at 99.07% purity by UPLC-MS/MS, analysed 24 August 2026 on lot APL-BPC10-2608-01, net content 10.02 mg, verification code OZ-HPLCMS-AL98; bacterial endotoxin 18.60 EU per vial by kinetic chromogenic LAL, analysed 24 August 2026, verification code OZ-ENDOTX-2APL.

Issued by Ozcanium Analytics . Covers every vial size of this compound; each report opens as the laboratory issued it.

  • Third-Party Purity COA (PDF, opens in a new tab) 99.07% purity by UPLC-MS/MS · net content 10.02 mg Analysed 24 August 2026 Verification code OZ-HPLCMS-AL98
  • Third-Party Endotoxin Test (PDF, opens in a new tab) Bacterial endotoxin 18.60 EU per vial by kinetic chromogenic LAL Analysed 24 August 2026 Verification code OZ-ENDOTX-2APL

Enter a code in the Ozcanium Analytics verification portal (opens in a new tab) to confirm the report against their own records.

The certificate as issued is reproduced below — pinch to zoom on a phone, or use Print / Save as PDF for a full-size copy.

Compound

BPC-157

Lot Number

APL-BPC10-2608-03

Analysis Date

17 August 2026

Method

HPLC / Mass Spectrometry

Purity

99.12%

Net Content

10.08 mg

CAS Number

137525-51-0

Formula

C62H98N16O22

Molecular Weight

1419.5 g/mol

Form

Lyophilised Powder

Manufactured

August 2026

Issued

18 August 2026

Document ID

APL-COA-BPC10-2608-03

Verification Code

Batch traceable

High Performance Liquid Chromatography (HPLC-UV) Chromatogram

Main peak integrated at 99.12% of total area; no single impurity peak exceeds 0.34%.

Peak List

#Time (min)Area% AreaIdentification
12.82015,1200.210—
23.08024,4800.340—
33.2407,136,64099.120BPC-157
43.75013,6800.190—
55.11010,0800.140—

Analytical Results

TestSpecificationResultStatus
AppearanceWhite/Off-White Lyophilised PowderConformsPASS
Identity (MS)ConfirmedConfirmedPASS
Purity (HPLC)≥98.0%99.12%PASS
Peptide Content95–105%98.7%PASS
Endotoxins<0.5 EU/mg<0.25 EU/mgPASS

BPC-157 10 mg

CAS Number: 137525-51-0

Liquid Chromatography Mass Spectrometry (LC-MS) Identity Analysis

Identity confirmation with SIM

Monitored (m/z)Detected (m/z)Relative Intensity
474474.171.1
711710.762.4
14211420.510.9

Detection assignment: BPC-157

Collected Mass Spectrum

Intensity ×10 7

Verification Protocol

  • Identity confirmed by mass spectrometry against the expected ion channels.
  • Purity measured by HPLC as peak area against all integrated impurity peaks.
  • Batch traceability: this document reports the lot number printed on the vial.
  • Analysis performed in-house by Australian Peptide Labs.

Supplied for laboratory research use only. Not a therapeutic good; not for human or veterinary use.

View BPC-157 in the catalogue · How to read this certificate

What this report shows

An HPLC purity result is the share of the detected signal that belongs to the main peptide peak. It does not confirm identity (that is mass spectrometry) and it is not net peptide content, which also counts water, counter-ions and salts in the vial.