KLOW certificate of analysis: lot APL-KLOW80-2610-05

Compound
KLOW
Lot
APL-KLOW80-2610-05
Laboratory
Supplier lab
Test
purity · HPLC
Result
99.45%
Tested
23 Oct 2026
Covers stock
80mg

KLOW 80 mg from batch APL-KLOW80-2610-05 was analysed on 23 October 2026 and measured 99.45% combined purity across GHK-Cu, KPV, TB-500 and BPC-157 by HPLC / Mass Spectrometry, passing all 5 release tests.

Combined purity

99.45%

Components

GHK-Cu, KPV, TB-500, BPC-157

Result

All 5 tests passed

Tested

23 October 2026

Method

HPLC / Mass Spectrometry

Net content

79.71 mg

Independent verification

KLOW 80 mg is independently verified by Ozcanium Analytics, an independent Australian laboratory, at 99.40% purity by UPLC-MS/MS, analysed 27 August 2026 on lot APL-KLOW80-2608-01, net content GHK-Cu 51.38 mg, KPV 10.58 mg, BPC-157 10.44 mg, TB-500 10.58 mg, verification code OZ-HPLCMS-BJ29.

Issued by Ozcanium Analytics . Covers every vial size of this compound; each report opens as the laboratory issued it.

  • Third-Party Purity COA (PDF, opens in a new tab) 99.40% purity by UPLC-MS/MS · net content GHK-Cu 51.38 mg, KPV 10.58 mg, BPC-157 10.44 mg, TB-500 10.58 mg Analysed 27 August 2026 Verification code OZ-HPLCMS-BJ29

Enter a code in the Ozcanium Analytics verification portal (opens in a new tab) to confirm the report against their own records.

The certificate as issued is reproduced below — pinch to zoom on a phone, or use Print / Save as PDF for a full-size copy.

Compound Mix

KLOW

Lot Number

APL-KLOW80-2610-05

Analysis Date

23 October 2026

Method

HPLC / Mass Spectrometry

Purity

99.45%

Net Content

79.71 mg

  • GHK-Cu 50.00 mg
  • KPV 10.10 mg
  • TB-500 10.11 mg
  • BPC-157 9.99 mg

Form

Lyophilised Powder

Manufactured

October 2026

Issued

24 October 2026

Document ID

APL-COA-KLOW80-2610-05

Verification Code

Batch traceable

High Performance Liquid Chromatography (HPLC-UV) Chromatogram

4 components resolved on a single gradient and assigned by retention time against individually run reference standards. Purity is reported as their combined peak area; the remaining 4 integrated peaks are unassigned process impurities. Component share of total peak area reflects UV response at 214 nm, not the mass ratio in the vial.

Peak List

#Time (min)Area% AreaAssignment
11.29714,3690.168—
21.4813,969,31746.411GHK-Cu
31.8471,976,83323.113KPV
42.20911,1190.130—
52.993949,11611.097TB-500
63.2871,610,51218.830BPC-157
73.75315,9080.186—
85.0895,5590.065—

Analytical Results

TestSpecificationResultStatus
AppearanceBlue/Blue-Green Lyophilised PowderConformsPASS
Identity (MS)All components confirmedConfirmedPASS
Purity (HPLC)≥98.0% combined99.45%PASS
Total Peptide Content95–105%99.0%PASS
Endotoxins<0.5 EU/mg<0.20 EU/mgPASS

GHK-Cu

PubChem CID: 133697840 · CAS Number: 49557-75-7

Formula: C14H24CuN6O4 · MW: 403.92 g/mol · In this vial: 50.00 mg

Liquid Chromatography Mass Spectrometry (LC-MS) Identity Analysis

Identity confirmation with SIM

Monitored (m/z)Detected (m/z)Relative Intensity
405404.931.53
427426.872.89

Detection assignment: GHK-Cu

Collected Mass Spectrum

Intensity ×10 7

KPV

PubChem CID: 125672 · CAS Number: 67727-97-3

Formula: C16H30N4O4 · MW: 342.4 g/mol · In this vial: 10.10 mg

Liquid Chromatography Mass Spectrometry (LC-MS) Identity Analysis

Identity confirmation with SIM

Monitored (m/z)Detected (m/z)Relative Intensity
343342.981.18
365364.470.83

Detection assignment: KPV

Collected Mass Spectrum

Intensity ×10 7

TB-500

PubChem CID: 16132341 · CAS Number: 77591-33-4

Formula: C212H350N56O78S · MW: 4963.4 g/mol · In this vial: 10.11 mg

Liquid Chromatography Mass Spectrometry (LC-MS) Identity Analysis

Identity confirmation with SIM

Monitored (m/z)Detected (m/z)Relative Intensity
828828.520.79
994993.921.68
12421242.10.65

Detection assignment: TB-500

Collected Mass Spectrum

Intensity ×10 7

BPC-157

PubChem CID: 9941957 · CAS Number: 137525-51-0

Formula: C62H98N16O22 · MW: 1419.5 g/mol · In this vial: 9.99 mg

Liquid Chromatography Mass Spectrometry (LC-MS) Identity Analysis

Identity confirmation with SIM

Monitored (m/z)Detected (m/z)Relative Intensity
474473.860.5
711710.971.77
142114210.29

Detection assignment: BPC-157

Collected Mass Spectrum

Intensity ×10 7

Verification Protocol

  • Identity confirmed separately for each component by mass spectrometry against its own expected ion channels.
  • Purity measured by HPLC as the combined area of every assigned component peak against all integrated impurity peaks.
  • Batch traceability: this document reports the lot number printed on the vial.
  • Analysis performed in-house by Australian Peptide Labs.

Supplied for laboratory research use only. Not a therapeutic good; not for human or veterinary use.

View KLOW in the catalogue · How to read this certificate

What this report shows

An HPLC purity result is the share of the detected signal that belongs to the main peptide peak. It does not confirm identity (that is mass spectrometry) and it is not net peptide content, which also counts water, counter-ions and salts in the vial.